Directory: Catalog > Water
Heaters > A.O. Smith
A.O.
Smith BTR Series with Automatic Flue Damper
MASTER-FIT® ... Self Cleaning, Super-Small, Easy to Install
- Three water connection options – Inlet and outlet connections located
top, front and rear offer more flexibility, easy incorporation into any plumbing
design.
- Fits in tight spaces – BTR models are as much as one foot shorter than
the models they will usually replace. Plus, they feature low clearances to combustibles
on all sides, top and rear.
- Application flexibility – Can be installed independently, manifolded
or connected to storage tanks. 14 BTR models offer inputs from 120,000 to 500,000
BTUs and capacities up to 100 gallons.
- Effikal automatic flue damper – Minimizes standby heat loss to achieve
80% thermal efficiency. Features reliable 360° rotation, service switch.
- Thermostat dual controller – Limits water temperature stacking.
- Intermittent electronic ignition – Eliminates standing pilot.
- On/Off power switch – Eliminates the need to wire a separate electrical
connection box.
- Exclusive CoreGard™ long-life stainless steel core anode rods
- Foam insulation
Three-year
limited tank warranty
- Handhole cleanout for easy cleaning
- Meets NSF requirements when equipped with optional leg kit
- Factory-installed T&P valve – Properly sized for each model.
- Canadian models available – See Master-Fit® Brochure AOSC60993.
- The Eliminator™ self-cleaning system – Helps reduce sediment buildup
inside the tank, so Master-Fit® water heaters stay energy-efficient, and last
longer.
- Meets ASRAE/IESNA 90.1-1999
- For your safety (and to comply with the warranty), have all water heater installations
and repairs completed by a licensed and insured contractor.
- General A.O. Smith Help

The Eliminator™ Action
By ordering this unit, you are certifying that it will be
installed by a reputable, licensed contractor, and that you agree with all terms
as set forth by JupiterHeating.com and the manufacturer.
| A.O. Smith
BTR Series Water Heater (Natural Gas) |
BTR-120NG
71 Gallon
120,000 BTU |
|
BTR-154NG
81 Gallon
154,000 BTU |
|
BTR-180NG
81 Gallon
180,000 BTU |
|
BTR-197NG
100 Gallon
199,000 BTU |
|
BTR-198NG
100 Gallon
199,000 BTU |
|
BTR-199NG
81 Gallon
190,000 BTU |
|
BTR-200NG
100 Gallon
199,000 BTU |
|
BTR-305A-NG
65 Gallon
305,000 BTU |
|
BTR-400NG
100 Gallon
399,000 BTU |
|
| A.O. Smith
BTR Series Water Heater (Propane) |
BTR-120LP
71 Gallon
120,000 BTU
AO Smith |
|
BTR-197LP
100 Gallon
199,000 BTU
AO Smith |
|
BTR-199LP
81 Gallon
190,000 BTU
AO Smith |
|
BTR-365A-LP
85 Gallon ASME
365,000 BTU
AO Smith |
|
BTR-400A-LP
100 Gallon ASME
399,000 BTU
AO Smith |
|
| A.O. Smith BTR Series Water
Heater (ASME Certification) |
BTR-200A
100 Gallon
199,000 BTU
Natural Gas
ASME Certification |
|
BTR-200A w LWCO
100 Gallon
199,000 BTU
With LWCO Relays and Switch
Natural Gas
ASME Certification |
|
BTR-250A-NG
100 Gallon
250,000 BTU
Natural Gas
ASME Certification |
|
BTR-251A-NG
62 Gallon
251,000 BTU
Natural Gas
ASME Certification |
|
BTR-275A-NG
100 Gallon
275,000 BTU
Natural Gas
ASME Certification |
|
BTR-365A-NG
85 Gallon
365,000 BTU
Natural Gas
ASME Certification |
|
BTR-400A-NG
100 Gallon
399,000 BTU
Natural Gas
ASME Certification |
|
BTR-500A-NG
85 Gallon
500,000 BTU
Natural Gas
ASME Certification |
|
Download Literature:
Loading times will vary depending on the speed of your Internet connection.
After the download is complete, use your browser's back arrow to return to this
page.
BTR
FAQ's
- What is the sequence of operation?
When the thermostat calls for heat, the relay in the draft hood assembly activates,
de-energizing the flue damper motor. When the spring fully opens the damper, power
flows to the IID (Intermittent Ignition Device). This activates the IID module
to open the pilot valve and also begin the sparking at the pilot burner assembly.
Once the pilot flame is established and confirmed back to the IID by the flame
sensor, the sparking is stopped and the main gas valve is opened so gas then flows
to the main burner. The lit pilot flame ignites the burners which continue heating
the water until the thermostat is satisfied. When the thermostat is satisfied
both main burners and pilot flame are extinguished and the damper motor is energized.
The damper motor keeps the damper closed until the next call for heat.
- What is the purpose of the damper assembly?
The damper plate on top of the heater closes when the burners go off in order
to retain heat within the tank. This reduces the stand-by heat loss and the overall
operating cost of the unit.
- What are the reset buttons on the heater for?
There are two reset buttons. The one on top is part of the damper assembly
and will need to be reset if the motor or the relay fail. Push once and release
to get one cycle of heating water. You will need to reset it again until a qualified
technician troubleshoots the system.
The other reset button is on the side of the tank and is labeled ECO (Energy
Cut Off). This is the safety temperature high limit which activates at 205º
F. To reset, allow the temperature to drop down below 120° F, then push
and release the button. Call a qualified technician immediately to diagnose cause
of overheating.
- What are some of the common Engineering Data?
See chart:
| Total Electrical Consumption |
Less than 2 Amps at 120 VAC |
| Thermostat Range |
Range is 120 F - 180 F 4, 5 differential |
| High Limit (ECO) Setting |
Opens at 205 F, re-setable below 120 F |
| Gas Pressure Requirements |
| Supply Pressure Min. - Max. > |
Natural 4.5" - 13.8" w.c. |
|
Propane 11" - 13.8" w.c. |
Manifold Pressure: |
Natural 3.5" w.c.
Propane 10" w.c. |
|
| Gas Valve Characteristics |
24 VAC step opening gas valve with the electrical resistance readings below:
- Pilot Valve 20ohms (+/- 5 ohms as measured between the two wires on the back
of the valve)
- Main Valve 68ohms (+/- 5 ohms as measured between the TH and TR terminals
on the valve)
|
| Flame Sense Signal |
0.7 DC MicoAmps |
| Transformer Data |
Step-down transformer 120 VAC / 24 VAC, 50/60 Hz, Class 2, 40 VA |
| Intermittent Ignition Device |
Honeywell IID model S8600M with 90 seconds trial for ignition followed by
a 5-minute lockout period, local sense. |
Information Source: A.O. Smith

[Home] [Catalog]
[Contact Us] [Parts] [Review
Shopping Cart ] [About Us / Terms of Sale]
[Boilers] [Radiant
Heating] [Water Heaters] [Plumbing]
[Pumps] [Indoor Air
Quality] [Insulation]
Purchase products securely with:
Manufacturers may change product specifications and information without notice.
Copyright 2008, JupiterHeating.com
& Jupiter Sales, LLC. All rights reserved.
|
Order securely 24/7!
|
We want your business!
|
|
Give us the opportunity to match
or beat any price published online!
|
|
Radiant Heat Packages
|
|

Have a radiant heating system designed
for you.
|
|