Directory: Catalog > Boilers
> A.O. Smith Water Heaters & Boilers
Burkay®
Genesis® Space Saver Mid-Range Efficiency Gas Boiler
84% Thermal Efficiency, Smaller Footprint, Extreme Venting Flexibility,
Outstanding Value
Genesis is a new generation of commercial boilers designed and engineered to
a new benchmark in installation and operational flexibility. It is proof that
mid-range efficiency boilers don’t have to be big, difficult to install,
or expensive, like so many ordinary boilers.
High-Efficiency Features: 
- Limitless applications – Standout choice for everything from schools,
apartment buildings, motels and hotels to light industrial and more.
- Space-saving design fits where others can’t – As much as 1/3rd
smaller than other boilers. With the optional stack rack, two units can be put
in the same space as one.
- Advanced fan-assisted combustion system – Optimizes gas/air ratio and
forces air mixture into the burners for more efficient combustion.
- Efficient copper heat exchanger design – Advanced heat exchanger design
uses integral-finned extruded copper tubes to increase transfer of heat which
translates into a high 83.7% thermal efficiency rating.
- Hook up-and-run simplicity – Just connect water, gas, electrical and
venting, set temperature, flip switch, and you’re off and running.
- Exclusive multi-mount exhaust fitting – Gives you option of either rear-or
top-venting connections. Greatly simplifies installation and manifolding of stacked
units.
- Extremely low-NOx emissions
- Dia-Scan™ II diagnostic system – Microprocessor-based control.
Monitors every electrical boiler function. Pinpoint diagnostic capabilities. Digital
LED Temperature display. Function status and fault LEDs. Plus or minus 1 degree
accuracy. Optional remote control panel and modem software.
- Meets ASRAE/IESNA 90.1-1999
- For your safety (and to comply with the warranty), have all water heater
installations and repairs completed by a licensed and insured contractor.
- For your safety (and to comply with the warranty), have all water heater installations
and repairs completed by a licensed and insured contractor.
- General A.O. Smith Help
Mechanical Venting Flexibility:
- Direct-vent pressurized combustion: Allows clean, uncontaminated air to be
drawn directly into unit. Flue gas by-products are expelled through wall to outside.
- Sidewall or vertical: The Genesis® boiler can be vented directly through
an outside wall or vertically through the roof.
- The rear-venting design allows units to be stacked squarely over one another
to save space and simplify manifolding.
| 
DiaScan™ II Diagnostic System
|

Genesis Outdoor Models Available.
|
|
Note: Quantities can be modified after you "Add to
Cart". The shopping cart will also give you a running total of the shipping
charges.
| Place Order |
| A.O. Smith Genesis
Gas Boiler - GB Series |
500,000 BTU
Natural Gas SKU: GB-500 |
|
750,000 BTU
Natural Gas SKU: GB-750NG
|
|
| A.O. Smith Genesis
Gas Boiler - GW Series
|
GW-200NG
199,900 BTU |
|
GW-300NG
300,000 BTU |
|
GW-400NG
399,900 BTU |
|
GW-500NG
500,000 BTU |
|
GW-650NG
650,000 BTU |
|
GW-750NG
750,000 BTU |
|
GW-1000NG
990,000 BTU |
|
GW-1300NG
1,300,000 BTU |
|
GW-1800NG
1,850,000 BTU |
|
GW-2100NG
2,100,000 BTU |
|
| See Propane
Pricing |
|
Download Literature:
Loading times will vary depending on the speed of your Internet connection.
After the download is complete, use your browser's back arrow to return to this
page.
Genesis
FAQS
- What is the thermal efficiency of this unit?
83.7%
- Can this unit be installed outside?
You can install this unit outside if you order the outdoor kit, part number
210333 and you will need supply the size of the unit.
- What are the electrical requirements for this unit?
You will need a 120V, 20 amp circuit to run this heater.
- How much water flow do you need to activate the flow switch?
Approximately 2 gpm to close.
- What are the pressure ratings for the pressure switches?
Blocked inlet = 0.20 negative inches
Blocked outlet = 0.20 positive inches
Blower prover = 0.30 positive inches
- Can these units be stacked?
These units can be stacked with the appropriate stack rack kit,
GW/GB 200 thru 400 part number 210427-001
GW/GB 500 thru 750 part number 210427-000
- What codes are available on these units?
FM, CSD-1, IRI, ILLINOIS, SCHOOL CODE, CALIFORNIA CODE. and NEW YORK CODE.
- Do these units come with a factory installed pump?
The GW models all come with a factory installed pump, but the GB units do
not (customer installed pumps).
- Do you have to use a storage tank with this unit?
This unit can be used in a hydronic application without a storage tank as
long as you use a primary/secondary plumbing arrangement.
- What type of combustion chamber does this unit have?
The unit has a stainless steel burner with a horizontal copper finned heat
exchanger.
- What kind of venting options does this unit have?
This unit has multiple venting options; choose from several conventional or
direct venting options. Multiple opening options; choose from inlet/outlet openings
leaving top of the boiler, inlet/outlet leaving the rear of the boiler or any
combination thereof. Exhaust outlet/combustion air intake openings can be easily
adjusted in the field to meet the needs of the application. Can be direct
vented for up to 35 without the aid of additional blowers; longer runs up
to 60, are possible with fan assisted venting. Can be vented vertically
with economical type B pipe (horizontal runs require stainless steel
venting materials).
Direct Vent kit:
GW/B 200 part number 210320-0: 60 feet equivalent direct vent
GW/B 300 part number 210320-1: 60 feet equivalent direct vent
GW/B 400 part number 210320-2: 35 feet equivalent direct vent
GW/B 500 part number 210320-2: 35 feet equivalent direct vent
GW/B 650 part number 210320-3: 35 feet equivalent direct vent
GW/B 750 part number 210320-3: 35 feet equivalent direct vent
Horizontal sidewall:
GW/B 200 part number 210320-0: 110 feet equivalent direct vent
GW/B 300 part number 210320-1: 110 feet equivalent direct vent
GW/B 400 part number 210320-2: 50 feet equivalent direct
vent
GW/B 500 part number 210320-2: 50 feet equivalent direct
vent
GW/B 650 part number 210320-3: 50 feet equivalent direct
vent
GW/B 750 part number 210320-3: 50 feet equivalent direct
vent
Horizontal extended direct and sidewall power vent kits:
GW/B 400-500: part number 210395-000
GW/B 650-750: part number 210395-001
Vertical direct vent terminal kits:
GW/B 200 part number 210317-000: 60 feet equivalent direct vent.
GW/B 300 part number 210317-001: 60 feet equivalent direct vent
GW/B 400 part number 210317-002: 35 feet equivalent direct vent
GW/B 500 part number 210317-002: 35 feet equivalent direct vent
GW/B 650 part number 210320-3: 50 feet equivalent
direct vent
GW/B 750 part number 210320-3: 50 feet equivalent
direct vent
- How much water does this unit hold?
The unit will hold approximately one gallon of water for every 100,000 BTUs
Information Source: A.O. Smith

[Home] [Catalog] [Contact
Us] [Parts] [Review
Shopping Cart ] [About Us / Terms of Sale]
[Boilers] [Radiant
Heating] [Water Heaters] [Plumbing]
[Pumps] [Indoor Air
Quality] [Insulation]
[Misc. Heating & Plumbing]
Purchase products securely with:
Manufacturers may change product specifications and information without notice.
Copyright 2008, JupiterHeating.com
& JupiterSales.com. All rights reserved.
|
Order securely 24/7!
|
We want your business!
|
|
Give us the opportunity to match
or beat any price published online!
|
|
Radiant Heat Packages
|
|

Have a radiant heating system designed
for you.
|
|