Here, by every measure is the world’s best engineered, high-efficiency hot water supply boiler. The Legend 2000®, which easily exceeds all national standards, brings together every detail in advanced boiler design: 90% thermal efficiency, virtually flawless performance, unmatched ease of installation, operation and service. Plus, astonishing Burkay® reliability and longevity.

Legendary Features:

  • Advanced combustion technology – Assures 90% thermal efficiency. This high efficiency is accomplished through advanced pre-mix technology–gas and air are precisely mixed for optimum
    burner performance. Cost Savings!
  • Exclusive heat exchanger design – A special integrated baffle design exposes more surface area to the combustion system. This patent-pending configuration eliminates the need for troublesome “V” baffles.
  • All waterways of copper, brass or bronze – High-quality metals, such as these, with similar metal-lurgical characteristics, greatly reduce stress on castings and minimizes the threat of electrolysis and leaks.
  • Gasketless heat exchanger and wet section – This superior gasketless wet section design assures reliability and longevity. No deterioration of gaskets exposed to heat and pressure. No leaks!
  • All stainless steel burner – A radial-fired stainless steel burner design. This laserwelded, non-ferrous corrosion-resistant Inconel™ 625 super alloy construction allows for quiet operation and years of reliable performance. 5-year warranty. No moving parts!
  • Compact design – Small footprint–23" X 32" saves valuable space and allows ease of entry and modular installations. The Legend 2000® fits easily through a standard 30" doorway (LW-500/750). Ideal for retrofits!
  • Dia-ScanTM II diagnostic system – Microprocessor-based control. Monitors every electrical boiler function. Pinpoint diagnostic capabilities. Digital LED Temperature display. Function status and fault LEDs. Plus or minus 1 degree accuracy. Optional remote control panel and modem software.
  • Hot surface ignition – Provides safe, reliable 120 volt ignition. Removable without pulling the burner.
  • Factory-mounted pump – hot water supply boiler only – Enclosed circulating pump mounted for ease of maintenance and cool operation away from venting.
  • Sealed combustion – Increases efficiency while reducing NOx. No flue spillage through barometric dampers. Environmentally Friendly.
  • Legendary jacket design – Easy lift-off front panel allows for optimum access to all components and controls. Total jacket cabinetry can be removed while unit is running. No pressurized jacket or gaskets.
  • Zero clearance – Versatile zero clearance design allows for maximum adaptability.
  • Factory tested – Every Legend unit is water and firetested to assure reliable operation.
  • Venting flexibility – Many convenient venting options to choose from. Options allow for direct-venting with protection from flue recirculation.
  • Warranty – Five-year limited warranty, backed by A.O. Smith’s reputation and over 400 service centers nationwide.
  • Meets ASRAE/IESNA 90.1-1999
  • For your safety (and to comply with the warranty), have all water heater installations and repairs completed by a licensed and insured contractor.
  • General A.O. Smith Help

Other Standard Features:

  • ASME 160# W.P.
  • ASME pressure valve
  • Low-air pressure switch
  • Pump and flow switch mounted
  • 24 volt controls
  • Brass drain valve
  • Pre-wired for Building Management Control
  • Low-gas pressure switch
  • Digital thermometers
  • Manual reset—Hi limit

Options:

  • Alarm bell
  • Pump post purge
  • Low-water cutoff
  • Through-the-wall venting
  • Direct/Sealed vent
  • Skid mounted systems
  • FM, CSD-1, IRI, Ill. School Code

Note: Quantities can be modified after you "Add to Cart". The shopping cart will also give you a running total of the shipping charges.

Place Order
A.O. Smith Burkay® Legend 2000® Boiler Natural Gas Propane
(LP Gas)
450,000 BTU
SKU: LW-500NG
$15,620.00
SKU: LW-500LP
$15,730.00
750,000 BTU
SKU: LW-750NG
$15,730.00
 
1,000,000 BTU
SKU: LW-1000NG
$16,280.00
 

Download Literature:
Loading times will vary depending on the speed of your Internet connection. After the download is complete, use your browser's back arrow to return to this page.

Burkay Legend FAQ's

  • On what fuels will this unit operate?

    Propane or Natural gas.

  • What is the thermal efficiency of this unit?

    90%

  • Can this unit be installed outside?

    This unit is not designed to operate outside

  • What are the electrical requirements for this unit?

    You will need a 120V, 30 amp circuit to run this heater.

  • How much water flow do you need to activate the flow switch?

    Approximately 2 gpm to close.

  • What is the minimum operating temperature of this unit?

    The minimum entering water temperature the unit should experience on a regular basis is 140° F.

  • What is operational temperature rise across the coil?

    The optimum temperature rise across the coil should be 20° F

  • Can these units be stacked?

    No

  • What codes are available on these units?

    FM, CSD-1, IRI, ILLINOIS, SCHOOL CODE, CALIFORNIA. CODE. and NEW YORK CODE.

  • Do these units come with a factory installed pump?

    The LW models all come with a factory installed pump, but the LB units do not (customer installed pumps).

  • Do you have to use a storage tank with this unit?

    This unit can be used in a hydronic application without a storage tank as long as you use a primary/secondary plumbing arrangement.

  • What type of combustion chamber does this unit have?

    The unit has a stainless steel burner with a radial fired design.

  • What kind of heat exchanger does this unit have?

    The heat exchanger is an extruded finned copper tubing exposing maximum surface area.

  • What kind of venting options does this unit have?

    This unit has multiple vent options but must use AL29-4c for the exhaust pipe since it is a Category IV water heater.

  • What is the maximum distance this unit can be vented?

    The total equivalent footage must not exceed 25 feet for intake or exhaust. Each 90 deg. elbow is equal to 5 feet.

  • How much water does this unit hold?

    The unit will hold approximately one gallon of water for every 100,000 BTUs

  • What is the minimum dynamic gas supply pressure?

    The heater needs 7” wc while running. Anything lower than that will create “hard starts”.

Information Source: A.O. Smith


Heating Supplies

[Home] [Catalog] [Contact Us] [Parts] [Review Shopping Cart ] [About Us / Terms of Sale]
[Boilers] [Radiant Heating] [Water Heaters] [Plumbing]
[Pumps] [Indoor Air Quality] [Insulation]
[Misc. Heating & Plumbing]


Purchase products securely with:
Visa, Mastercard, American Express

Manufacturers may change product specifications and information without notice.

Copyright 2008, JupiterHeating.com & JupiterSales.com. All rights reserved.

Order securely 24/7!



Click to verify BBB accreditation and to see a BBB report.

We want your business!

Give us the opportunity to match or beat any price published online!


Radiant Heat Packages

Kitec, Warmrite hydronic heating

Have a radiant heating system designed for you.