JupiterHeating.com - Heating and Plumbing

Featured
Product Lines

Directory: Catalog > Insulation > Astro-Foil Insulation

Astro-E Reflective InsulationAstro-E (foil/bubble/foil) Reflective Insulation

The Revolutionary  Insulating Material That's Safe,  Effective, Versatile And Easy To Install.

ASTRO-E reflective foil insulation consists of a layer of polyethylene bubble film sandwiched between two layers of 99.9% pure aluminum foil, making a structure 1/4-inch thick. ASTRO-E is a lighter weight, less expensive structure that, in many applications will give performance comparable to ASTRO-FOIL. Standard roll sizes 48" x 125' and 72" x 125'.

  • It reflects heat - keeps buildings warm in Winter and cool in Summer.
  • It stops air infiltration - seals drafty buildings.
  • It acts as a vapor barrier.
  • It is strong, light weight, clean and does not degrade over time.
  • It is easy and fast to install - usually saves up to 50% labor time.
  • It improves comfort AND saves money.
  • General information about Astro-Foil Reflective Insulation
More Efficient, Safer To Use and Easier To Install Than Regular Bulk Mineral Fiber Or Foamboard Insulation For Pre-Engineered Metal and Post-Frame Buildings.

ASTRO-FOIL is a revolutionary type of industrial, commercial and general purpose insulation incorporating state-of-the-art technology in design and manufacture. It includes a building code approved vapor barrier, air infiltration barrier and powerful insulation all in one.

Its unique composite design consists of layers of polyethylene air bubble pockets, surrounded by a thin layer of reflective aluminum foil that is inorganic, water-resistant, puncture-resistant, termite and fungus resistant, non-allergenic and inhospitable to nesting rodents.

ASTRO-FOIL is easy to install-it's thin, pliable, lightweight design is especially suited for pre-engineered and post-frame buildings. ASTRO-FOIL offers increased energy efficiency over traditional insulation products. And it's safe... there are no protective masks, gloves or safety glasses required. Standard 4'and 6' wide rolls can be easily trimmed with a utility knife or pair of scissors to fit any application. ASTRO-FOIL's lightweight design makes it easy on your building's design load.

 

Note: Quantities can be modified after you "Add to Cart". The shopping cart will also give you a running total of the shipping charges.

Place Order
48 in. x 125 ft. Bulk Roll
SKU: E5
$310.00
72 in. x 125 ft. Bulk Roll
SKU: E
$455.00

Download Literature:
Loading times will vary depending on the speed of your Internet connection. After the download is complete, use your browser's back arrow to return to this page.

Guidelines for all Astro-Foil Installations

  1. ASTRO-FOIL works best when there is a 3/4' air space on each side of the insulation. (Larger air space is fine but a smaller one reduces its thermal effectiveness.)
     
  2. ASTRO-FOIL should always be installed on the inside of the structure.
     
  3. ASTRO-FOIL will not cure existing problems. Leaking roofs, rot or mold situations or other moisture or structural problems should be corrected before installation.
     
  4. Any deteriorated wiring should be replaced prior to installing ASTRO-FOIL.
     
  5. ASTRO-FOIL should be at least 3' from any heat producing fixtures, chimneys, blowers, etc. NEVER install ASTRO-FOIL directly above lighting or other heat producing devices.
     
  6. Always turn off all electricity in the area when installing ASTRO-FOIL.

 

ASTRO-FOIL REFLECTIVE MATERIAL

ASTRO-FOIL reflective installation consists of two layers of aluminum foil laminated to the outside of two layers of heavy-duty polyethylene air-bubble cushioning. These bubbles form trapped air spaces between the foil surfaces to give the structure excellent 'R' values. Because ASTRO-FOIL II is also impervious to moisture and air currents, it is an ideal convection and vapor barrier. ASTRO-FOIL'S surfaces reflect heat in both directions to keep you warm in the Winter and cooler in Summer.

Some of the many uses for ASTRO-FOIL

In Agricultural Buildings
In Beverage Coolers
In Commercial Buildings
In Confinement Structures
In Industrial Buildings
In Warehouses
In Workshops
In Post Frame Construction
Behind Freezers
Behind Woodstoves
Behind Refrigeration Coils
For Concrete-Curing Blankets
Under Tents
Under Sleeping Bags
Under Mattresses
As Padded Foot Warmers
As Cargo Liners in Trucks
As A Window Covering
As A Survival Blanket
As Pharmaceutical Packaging
As Duct Wrap
On Overhead Doors
TECHNICAL DATA
  
Thickness:
Weight:
Flame Spread
    (ASTM E-84-81A):
Fire Rating:
Linear Shrinkage:
Puncture Resistance:
R-Value*:
Emittance C1371:
Reflectance:
Degradation:
U-Value (Btu/ft. 2hro F):
Water Transmission Rate
    ASTME96:
Fungi Resistant
Astro-Foil
5/16' Nominal (8mm)
1.25 oz. per sq. ft. (382 g/m2)

20 Flame/30 Smoke
Class A/Class1
None
66 lbs. per sq. in. (455 kPa)
15 (down) 7.31 (Horiz.) 5.4 (Up)
0.03-0.04
0.96-0.97
0
0.0820 (down) 0.119 (Horiz.) 0.139 (Up)

0.02
Astro-E
3/16' Nominal (6.35mm)
.811 oz. per sq. ft. (207 g/m2)

15 Flame/30 Smoke
Class A/Class 1
None
63 lbs. per sq. in. (434 kPa)
14.5 (Down) 7.0 (Horiz.) 4.9 (Up)
0.03-0.04
0.96-0.97
0
0.0771 (down) 0.109 (Horiz.) 0.119 (Up)

0.02

HUD/FHA Projects: Meets HHI 1252B / California License: TF1213 / California Registry: CAT213 (NJ) / Canada CCMC 11978

* These values are obtained in a C236 hot box test and represent the R-Value of the cavity that includes the surround air spaces. The measurements were made in a cavity framed with standard 2Óx4Ó lumber. For complete details regarding methodology, contact your nearest innovative Energy Sales Office. ASTRO-FOILÕS ability to reflect heat in open applications is not fully measured by this test. ItÕs that extra reflective capability that makes it possible for ASTRO-FOIL to keep people and animals comfortable all year long.

Compliance
Agency/Organization
ASTRO-FOIL
ASTRO-E
1995 CABO One and
Two Family Dwelling Code
Section 319.1
Section 319.1
California Bureau of Home
Furnishings Insulation program
(Reg.No.)
CA-T338
CA-T338
City of Los Angeles
RR-8403
RR-8403
Miami Dade County, Florida
Building Code and Product
Review Committee
98-0413.01
98-0413.01
Minnesota Dept. of Energy
Yes
Yes
1999 National Building Code
Section 803.4
Section 803.4
1997 Standard Building Code
Section 803.2
Section 803.2
1997 Uniform Building Code
Section 707.3
Section 707.3

 

WARNING: Reflective bubble-pack insulation will ignite if exposed to fire or sufficient heat and intensity. Protect insulation from exposure to open flame or other ignition sources during shipping, storage and installation.

The manufacturer believes this information and recommendations herein to be accurate and reliable. However, since use conditions are not within its control the manufacturer does not guarantee results from use of such products or other information herein and disclaims all liability from any resulting damage or loss. NO WARRANTY, EXPRESSED OR IMPLIED, IS GIVEN AS TO THE MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR OTHERWISE WITH RESPECT TO THE PRODUCTS REFERRED TO. Freedom from patents of PACTIV or others is not to be inferred.

Astro-Foil is a registered trademark of Pactiv Corporation.

Information Source: Innovative Energy, Inc.


Heating Supplies

[Home] [Catalog] [Contact Us] [Parts] [Review Shopping Cart ] [About Us / Terms of Sale]
[Boilers] [Radiant Heating] [Water Heaters] [Plumbing]
[Pumps] [Indoor Air Quality] [Insulation]
[Misc. Heating & Plumbing]


Purchase products securely with:
Visa, Mastercard, American Express

Manufacturers may change product specifications and information without notice.

Copyright 2008, JupiterHeating.com & JupiterSales.com. All rights reserved.

Order securely 24/7!



Click to verify BBB accreditation and to see a BBB report.

We want your business!

Give us the opportunity to match or beat any price published online!


Radiant Heat Packages

Kitec, Warmrite hydronic heating

Have a radiant heating system designed for you.