ASTRO-E reflective foil insulation consists of a layer of polyethylene bubble
film sandwiched between two layers of 99.9% pure aluminum foil, making a structure
1/4-inch thick. ASTRO-E is a lighter weight, less expensive structure that, in
many applications will give performance comparable to ASTRO-FOIL. Standard roll
sizes 48" x 125' and 72" x 125'.
- It reflects heat - keeps buildings warm in Winter and
cool in Summer.
- It stops air infiltration - seals drafty buildings.
- It acts as a vapor barrier.
- It is strong, light weight, clean and does not degrade
over time.
- It is easy and fast to install - usually saves up to
50% labor time.
- It improves comfort AND saves money.
- General information
about Astro-Foil Reflective Insulation
More Efficient, Safer To Use and Easier To Install Than Regular Bulk Mineral
Fiber Or Foamboard Insulation For Pre-Engineered Metal and Post-Frame Buildings.
ASTRO-FOIL
is a revolutionary type of industrial, commercial and general purpose insulation
incorporating state-of-the-art technology in design and manufacture. It includes
a building code approved vapor barrier, air infiltration barrier and powerful
insulation all in one.
Its unique composite design consists of layers
of polyethylene air bubble pockets, surrounded by a thin layer of reflective aluminum
foil that is inorganic, water-resistant, puncture-resistant, termite and fungus
resistant, non-allergenic and inhospitable to nesting rodents.
ASTRO-FOIL is easy to install-it's thin, pliable,
lightweight design is especially suited for pre-engineered and post-frame buildings.
ASTRO-FOIL offers increased energy efficiency over traditional insulation products.
And it's safe... there are no protective masks, gloves or safety glasses required.
Standard 4'and 6' wide rolls can be easily trimmed with a utility knife or pair
of scissors to fit any application. ASTRO-FOIL's lightweight design makes it easy
on your building's design load.
Note: Quantities can be modified after you "Add to
Cart". The shopping cart will also give you a running total of the shipping
charges.
| Place Order |
48 in. x 125 ft. Bulk Roll
SKU: E5 |
|
72 in. x 125 ft. Bulk Roll
SKU: E |
|
Download Literature:
Loading times will vary depending on the speed of your Internet connection.
After the download is complete, use your browser's back arrow to return to this
page.
Guidelines for all Astro-Foil Installations
- ASTRO-FOIL works best when there is a 3/4' air
space on each side of the insulation. (Larger air space is fine but a smaller
one reduces its thermal effectiveness.)
- ASTRO-FOIL should always be installed on the
inside of the structure.
- ASTRO-FOIL will not cure existing problems. Leaking
roofs, rot or mold situations or other moisture or structural problems should
be corrected before installation.
- Any deteriorated wiring should be replaced prior
to installing ASTRO-FOIL.
- ASTRO-FOIL should be at least 3' from any heat
producing fixtures, chimneys, blowers, etc. NEVER install ASTRO-FOIL directly
above lighting or other heat producing devices.
- Always turn off all electricity in the area when
installing ASTRO-FOIL.
 |
ASTRO-FOIL REFLECTIVE MATERIAL
ASTRO-FOIL reflective installation consists of two layers
of aluminum foil laminated to the outside of two layers of heavy-duty polyethylene
air-bubble cushioning. These bubbles form trapped air spaces between the foil
surfaces to give the structure excellent 'R' values. Because ASTRO-FOIL II is
also impervious to moisture and air currents, it is an ideal convection and vapor
barrier. ASTRO-FOIL'S surfaces reflect heat in both directions to keep you warm
in the Winter and cooler in Summer.
Some of the many uses for
ASTRO-FOIL
|
In Agricultural Buildings
In Beverage Coolers
In Commercial Buildings
In Confinement Structures
In Industrial Buildings
In Warehouses
In Workshops
In Post Frame Construction
Behind Freezers |
Behind Woodstoves
Behind Refrigeration Coils
For Concrete-Curing Blankets
Under Tents
Under Sleeping Bags
Under Mattresses
As Padded Foot Warmers
As Cargo Liners in Trucks
As A Window Covering |
As A Survival Blanket
As Pharmaceutical Packaging
As Duct Wrap
On Overhead Doors |
| TECHNICAL
DATA |
Thickness:
Weight:
Flame Spread (ASTM E-84-81A):
Fire Rating:
Linear Shrinkage:
Puncture Resistance:
R-Value*:
Emittance C1371:
Reflectance:
Degradation:
U-Value (Btu/ft. 2hro F):
Water Transmission Rate ASTME96:
Fungi Resistant |
Astro-Foil
5/16' Nominal (8mm)
1.25 oz. per sq. ft. (382 g/m2)
20 Flame/30 Smoke
Class A/Class1
None
66 lbs. per sq. in. (455 kPa)
15 (down) 7.31 (Horiz.) 5.4 (Up)
0.03-0.04
0.96-0.97
0
0.0820 (down) 0.119 (Horiz.) 0.139 (Up)
0.02 |
Astro-E
3/16' Nominal (6.35mm)
.811 oz. per sq. ft. (207 g/m2)
15 Flame/30 Smoke
Class A/Class 1
None
63 lbs. per sq. in. (434 kPa)
14.5 (Down) 7.0 (Horiz.) 4.9 (Up)
0.03-0.04
0.96-0.97
0
0.0771 (down) 0.109 (Horiz.) 0.119 (Up)
0.02 |
| HUD/FHA Projects: Meets HHI 1252B / California License:
TF1213 / California Registry: CAT213 (NJ) / Canada CCMC 11978
* These values are obtained in a C236 hot box test and represent the R-Value
of the cavity that includes the surround air spaces. The measurements were made
in a cavity framed with standard 2Óx4Ó lumber. For complete details regarding
methodology, contact your nearest innovative Energy Sales Office. ASTRO-FOILÕS
ability to reflect heat in open applications is not fully measured by this test.
ItÕs that extra reflective capability that makes it possible for ASTRO-FOIL to
keep people and animals comfortable all year long. |
Compliance
Agency/Organization |
ASTRO-FOIL |
ASTRO-E |
1995 CABO One and
Two Family Dwelling Code |
Section 319.1 |
Section 319.1 |
California Bureau of Home
Furnishings Insulation program
(Reg.No.) |
CA-T338 |
CA-T338 |
| City of Los Angeles |
RR-8403 |
RR-8403 |
Miami Dade County, Florida
Building Code and Product
Review Committee |
98-0413.01 |
98-0413.01 |
| Minnesota Dept. of Energy |
Yes |
Yes |
| 1999 National Building Code |
Section 803.4 |
Section 803.4 |
| 1997 Standard Building Code |
Section 803.2 |
Section 803.2 |
| 1997 Uniform Building Code |
Section 707.3 |
Section 707.3 |
WARNING: Reflective bubble-pack insulation will ignite if exposed
to fire or sufficient heat and intensity. Protect insulation from exposure to
open flame or other ignition sources during shipping, storage and installation.
The manufacturer believes this information and recommendations herein
to be accurate and reliable. However, since use conditions are not within its
control the manufacturer does not guarantee results from use of such products
or other information herein and disclaims all liability from any resulting damage
or loss. NO WARRANTY, EXPRESSED OR IMPLIED, IS GIVEN AS TO THE MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, OR OTHERWISE WITH RESPECT TO THE PRODUCTS REFERRED
TO. Freedom from patents of PACTIV or others is not to be inferred.
Astro-Foil is a registered trademark of Pactiv Corporation. |
|
Information Source: Innovative Energy, Inc.

[Home] [Catalog] [Contact
Us] [Parts] [Review
Shopping Cart ] [About Us / Terms of Sale]
[Boilers] [Radiant
Heating] [Water Heaters] [Plumbing]
[Pumps] [Indoor Air
Quality] [Insulation]
[Misc. Heating & Plumbing]
Purchase products securely with:
Manufacturers may change product specifications and information without notice.
Copyright 2008, JupiterHeating.com
& JupiterSales.com. All rights reserved.
|