Astro-Foil
Reflective Insulation (foil/bubble/bubble/foil)

ASTRO-FOIL reflective foil insulation consists of two layers of polyethylene
bubble film sandwiched between two layers of 99.9% pure aluminum foil, making
a structure 5/16-inch thick. Depending upon the application, ASTRO-FOIL can outperform
6" of mass insulation in all climates. Even higher performance can be expected
in hot, humid climates.
ASTRO-FOIL is excellent as a primary insulation for buildings of all types.
Preferred by installers and building owners because it is safe to handle, lightweight
and works especially well in limited space. There are numerous applications for
residential, commercial, industrial and agricultural buildings. Standard roll
size: 48" x 125' & 72" x 125', other sizes available as shown below.
- It reflects heat - keeps buildings warm in Winter and
cool in Summer.
- It stops air infiltration - seals drafty buildings.
- It acts as a vapor barrier.
- It is strong, light weight, clean and does not degrade
over time.
- It is easy and fast to install - usually saves up to
50% labor time.
- It improves comfort AND saves money.
- Download Literature: Loading times will vary depending on the speed of your Internet connection.
After the download is complete, use your browser's back arrow to return to this
page.
Note: Quantities can be modified after you "Add to
Cart". The shopping cart will also give you a running total of the shipping
charges.
| Place Order* |
Astro-Foil Reflective Insulation
16 in. x 50 ft Roll
AJ |
|
Astro-Foil Reflective Insulation
16 in. x 125 ft Roll
AL |
|
Astro-Foil Reflective Insulation
24 in. x 50 ft Roll
AA |
|
| Astro-Foil Reflective Insulation
24 in. x 125 ft Roll
AM |
|
Astro-Foil Reflective Insulation
48 in. x 50 ft Roll
A1 |
|
| Astro-Foil Reflective Insulation
48 in. x 125 ft Roll
A9 |
|
Astro-Foil Reflective Insulation
60 in. x 125 ft Roll
A5 |
|
Astro-Foil Reflective Insulation
72 in. x 125 ft Roll
A |
|
See Also:
GUIDELINES FOR ALL ASTRO-FOIL INSTALLATIONS
-
ASTRO-FOIL works best when there is a 3/4'
air space on each side of the insulation. (Larger air space is fine but a smaller
one reduces its thermal effectiveness.)
-
ASTRO-FOIL should always be installed on the
inside of the structure.
-
ASTRO-FOIL will not cure existing problems.
Leaking roofs, rot or mold situations or other moisture or structural problems
should be corrected before installation.
-
Any deteriorated wiring should be replaced
prior to installing ASTRO-FOIL.
-
ASTRO-FOIL should be at least 3' from any heat
producing fixtures, chimneys, blowers, etc. NEVER install ASTRO-FOIL directly
above lighting or other heat producing devices.
-
Always turn off all electricity in the area
when installing ASTRO-FOIL.
Technical Data:
- Thickness: 5/16' Nominal (8mm)
- Weight: 1.25 oz. per sq ft (382 g/m2)
- Flame Spread (ASTM E-84-81A): 20
- Flame/30 Smoke Fire Rating: Class A/Class1
- Linear Shrinkage: None
- Puncture Resistance: 66 lb per sq in. (455 kPa)
- R-Value*: 15 (down) 7.31 (Horiz.) 5.4 (Up)
- Emittance C1371: 0.03-0.04
- Reflectance :0.96-0.97
- Degradation: 0
- U-Value (Btu/ft. 2hro F):0.0820 (down) 0.119 (Horiz.) 0.139 (Up)
- Water Transmission Rate ASTME96: 0.02
Information Source: Innovative Energy

|