MINI-RESTER
1/2 & 3/4 inch male sweat single fixture water hammer arrester
Rough-in sweat to nearly any copper piping system on the supply side of any valve
or fixture. Provides a permanent and affordable solution to water hammer. Engineered
specifically for single fixture residential or light commercial use. |
|
MINI-RESTER 1/2 in. male sweat connection
Sioux Chief 660-SB |
|
MINI-RESTER
straight compression single
fixture water hammer arrester
Install
on to any 1/2 in. CTS leg or riser. Especially popular in retrofitting 1/2 in.
air chambers. Provides a permanent and affordable solution to water hammer. Engineered
specifically for single fixture residential or light commercial use. |
|
|
MINI-RESTER 5/8 in. O.D. compression connection
Spec Sheet
Sioux Chief 660-CB |
|
MINI-RESTER
toilet connection single
fixture water hammer arrester
Works great for toilets with quick-closing ballcocks.
Provides a permanent and affordable solution to water hammer. Captured plastic
nut and EPDM nose cone for easy installation. Hides under toilet tank. |
|
|
Male ballcock thread x female ballcock thread - CLAMSHELL
Spec Sheet
Sioux Chief 660-TK |
|
MINI-RESTER
laundry single fixture
water hammer arrester
Install behind the washing machine. Solenoid
valves are a typical cause of water hammer. Provides a permanent and affordable
solution to water hammer. Engineered specifically for single fixture residential
or light commercial use. |
|
|
MINI-RESTER Female swivel hose thread x male
hose thread connection - CLAMSHELL
Spec Sheet
Sioux Chief 660-H |
|
MINI-RESTER
1/2 inch MIP single
fixture water hammer arrester
Install
on any new rough-in or retrofit installation with 1/2 in. FIP fittings. Provides
a permanent and affordable solution to water hammer. Engineered specifically for
single fixture residential or light commercial use. |
|
|
MINI-RESTER 1/2 in. MIP thread connection
- CLAMSHELL
Spec Sheet
Sioux Chief 660-2 |
|
HYDRA-RESTER
engineered water hammer arrester
Designed to keep system surge pressure to
150 PSIG or below. Certified by the American Society of Sanitary Engineering to
the ANSI/ASSE 1010 Standard. Lifetime cycle tested at U.S. Testing Laboratories
in Fairfield NJ to withstand 10000 shock cycles. Maximum working temperature:
250°. Maximum working pressure: 350°. Burst tested to: 2,900 PSIG. |
|
Spec Sheet
|
HYDRA-RESTER 1/2 in. MIP Connection, Unit size=A
Length=6-1/2 in., B=1-3/8 in.
fixture unit cap=1-11, cubic inch volume=5
Sioux Chief 652-A |
|
HYDRA-RESTER 3/4 in. MIP Connection, Unit size=B
Length=8-3/4 in., B=1-3/8 in.
fixture unit cap=12-32, cubic inch volume=7 Sioux Chief 653-B |
|
HYDRA-RESTER 1/2 in. MALE Sweat Connection, Unit size=A
Length=8-1/4 in., B=1-3/8 in.
fixture unit cap=1-11, cubic inch volume=5 Sioux Chief 652-AS |
|
HYDRA-RESTER 3/4 in. MALE Sweat Connection, Unit
size=B
Length=10 in., B=1-3/8 in.
fixture unit cap=12-32, cubic inch volume=7 Sioux Chief 653-BS |
|